VX-3008F
機框
VX-3008F
VX-3008F為VX-3000系列的控制主機,將必要的設備整合為一體,並採用模組式數位功率放大器,大幅度減少機櫃安裝所需要的空間。透過網路型連線設計,分 散式或者集中管理都能輕鬆對應,簡易安裝與遠端連線設定,節省更多人力及時間。
- 最大3組放大模組(8回路分區對2放大器切換式+備援放大器;或8回路分區自由設定對應放大器
- 輸入/輸出訊號可透過DSP功能調整
- 喇叭回路狀態指示、故障偵測與燈號測試按鈕
Network I/F: 100BASE-TX
Network Protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, FTP, HTTP, NTP
Spanning tree Protocol: RSTP
Audio Transmission System: TOA Packet Audio*1
Audio Encoding Method: PCM
Audio Sampling Frequency: 48 kHz
Audio Quantifying Bit Number: 16 bits
Connection Device: VX-3004F, VX-3008F, VX-3016F, NX-300, VX-3000PM, VX-3000CT, Switching HUB
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5) or greater
Number of Stages of Cascade connection:Up to 7
Maximum Cable Distance: 100 m (328.08 ft)
Audio input level: 0 dB (*2) Power feed: Max. 1 A per connector Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5) or greater
Maximum Cable Distance: 1200 m (3937.01 ft)
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
Maximum Cable Distance: 5 m (16.4 ft)
Connection Device: VX-3004F, VX-3008F, VX-3016F
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
Maximum Cable Distance: 800 m (2624.67 ft)
Sensitivity:
LINE: −20 dB*2, MIC: −60 dB*2
LINE/MIC/ANC Sensor (changeable with setting software)
Gain Control: volume adjustable with volume control (internal front panel) −∞ to 0 dB
Input Impedance: 47 kΩ, electronically-balanced
Frequency Response: 40 Hz to 20 kHz ±1 dB (at DA CONTROL LINK, 0 dB output)
Distortion: 1% or less (at DA CONTROL LINK, 0 dB output, 1 kHz)
Signal to Noise Ratio: 60 dB or more (at DA CONTROL LINK, A-weighted)
Phantom Power Supply: 24 V DC, can be set with setting software
Connector: Removable terminal block (6 pins) x 2
Fault Detection System: Short circuit, Open circuit, Method: Voltage detect
Connector: RJ45 connector,
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5) or greater
Hysteresis: 0 to +10 dB, Hold time: 10 ms – 10 s
Settable for each audio input
Exclusive outputs: 3 with CONTROL OUTPUT 2 GENERAL FAULT, CPU FAULT, CPU OFF)
No-voltage make contact, electrical contact output, control current: 10 mA, withstand voltage: 28 V DC
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
control current: 2 mA to 5 A, withstand voltage: 125 V AC, 40 V DC
Connector: Removable terminal block (12 pins) x 2
Settable for each audio input and RS LINK (A/B)
Parametric equalizer: 20 Hz – 20 kHz, ±15 dB, Q: 0.267 – 69.249
Filtering: High-pass filter 20 Hz – 20 kHz, 6 dB/oct, 12 dB/oct
Low-pass filter 20 Hz – 20 kHz, 6 dB/oct, 12 dB/oct
High shelving filter 6 – 20 kHz, ±15 dB
Low shelving filter 20 – 500 Hz, ±15 dB
Notch filter (amplifier output only) 20 Hz – 20 kHz, Q: 8.651 – 69.249
All-pass filter (amplifier output only) 20 Hz – 20 kHz, Q: 0.267 – 69.249
Horn equalizer (amplifier output only) 20 kHz, 0 to +18 dB (0.5 dB steps)
Ratio: 1:1, 1.1:1, 1.2:1, 1.3:1, 1.5:1, 1.7:1, 2:1, 2.3:1, 2.6:1, 3:1, 4:1, 5:1, 7:1, 8:1, 10:1, 12:1, 20:1, ∞:1
Attack time: 0.2 ms – 5 s
Release time: 10 ms – 5 s
Gain: –∞ to +10 dB
Knee type: hard knee, middle knee, soft knee
Sensor input reference level fine adjustment
Maximum output signal level control: –15 to 0 dB
Minimum output signal level control: –18 to –3 dB
Sample time setting: 10 s, 20 s, 30 s, 1 min, 5 min
Gain ratio setting: (Ambient noise: Output signal level) 6:3, 5:3, 4:3, 3:3, 3:4, 3:5, 3:6
Ambient noise measuring frequency setting: 20 Hz – 20 kHz, 3 points
Daily program: 50 events, 10 types
Holiday program: 50 types
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (17 pins) ... 1
Fault Detection System: Short circuit, Open circuit, Ground fault,
Method: Impedance or End of line
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (2 pins) x 2
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (2 pins) x 4
DA CONTROL LINK x 3,
DA OUTPUT LINK x 3 (Used only when a power amplifier module is installed)
FAULT STATUS (yellow): GENERAL x 1, UNIT x 1, NETWORK x 1, EMG MIC x 1, FUSE x 1, POWER x 1, CPU x 1, ZONE x 8
AMPLIFIER: PEAK (red) x 3, SIGNAL (green) x 3, OPERATE (green) x 3, POWER (green) x 3
Test Switch x 1 (LAMP TEST)
Setting Switch: ID NUMBER, RESET, IMPEDANCE, Setting (internal front panel)
(*2) 0 dB = 1 V
(*3) Module: Digital power amplifier module, Line output module
請下載資料以獲取完整規格。
Frame for 3 amplifier modules with 8 monitored speaker outputs.
Two amplifier modules can be assigned to any speaker output.
Speaker outputs with overlapping amplifiers will automatically choose the amplifier which signal has to be transmitted.
This allows a simultaneous broadcast of two different audio signals per frame to achieve an interruption-free BGM operation during a paging.
The third amplifier module can be used as standby amplifier.
Up to 4 base frames of this type can be cascaded to increase the number of assignable speaker outputs.
Monitoring is possible by impedance surveillance or by using an end-of-line module.
Settings for impedance deviation to indicate an open or shorted line can be individually set for every output.
4 general balanced audio inputs (microphone/line level) and 2 inputs for up to 8 remote microphones including up to two emergency microphones.
The signals at the general audio inputs can be mixed.
All mandatory indications and controls regarding EN54-16 can be found on the front panel.
Fault indication for every speaker output line.
Redundant network connection (Ethernet) of the base frame with RSTP via two RJ45 ports.
請登入以存取更多技術資料,例如軟體、韌體或EASE檔案。