VX-3004F
機框
VX-3004F
VX-3004F為VX-3000系列的控制主機,將必要的設備整合為一體,並採用模組式數位功率放大器,大幅度減少機櫃安裝所需要的空間。透過網路型連線設計,分 散式或者集中管理都能輕鬆對應,簡易安裝與遠端連線設定,節省更多人力及時間。
- 最大4組放大模組(1回路分區對1放大器,4回路AB分區;或3回路AB分區+備援放大器)
- 輸入/輸出訊號可透過DSP功能調整
- 喇叭回路狀態指示、故障偵測與燈號測試按鈕
Network I/F: 100BASE-TX
Network Protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, FTP, HTTP, NTP
Spanning tree Protocol: RSTP
Audio Transmission System: TOA Packet Audio*1
Audio Encoding Method: PCM
Audio Sampling Frequency: 48 kHz
Audio Quantifying Bit Number: 16 bits
Connection Device: VX-3004F, VX-3008F, VX-3016F, NX-300, VX-3000PM, VX-3000CT, Switching HUB
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5) or greater
Number of Stages of Cascade connection:Up to 7
Maximum Cable Distance: 100 m (328.08 ft)
Audio input level: 0 dB (*2) Power feed: Max. 1 A per connector Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5) or greater
Maximum Cable Distance: 1200 m (3937.01 ft)
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
Maximum Cable Distance: 5 m (16.4 ft)
Connection Device: VX-3004F, VX-3008F, VX-3016F
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
Maximum Cable Distance: 800 m (2624.67 ft)
Sensitivity:
LINE: −20 dB*2, MIC: −60 dB*2
LINE/MIC/ANC Sensor (changeable with setting software)
Gain Control: volume adjustable with volume control (internal front panel) −∞ to 0 dB
Input Impedance: 47 kΩ, electronically-balanced
Frequency Response: 40 Hz to 20 kHz ±1 dB (at DA CONTROL LINK, 0 dB output)
Distortion: 1% or less (at DA CONTROL LINK, 0 dB output, 1 kHz)
Signal to Noise Ratio: 60 dB or more (at DA CONTROL LINK, A-weighted)
Phantom Power Supply: 24 V DC, can be set with setting software
Connector: Removable terminal block (6 pins) x 2
Fault Detection System: Short circuit, Open circuit, Method: Voltage detect
Connector: RJ45 connector,
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5) or greater
Hysteresis: 0 to +10 dB, Hold time: 10 ms – 10 s
Settable for each audio input
Exclusive outputs: 3 with CONTROL OUTPUT 2 GENERAL FAULT, CPU FAULT, CPU OFF)
No-voltage make contact, electrical contact output, control current: 10 mA, withstand voltage: 28 V DC
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP) or greater
control current: 2 mA to 5 A, withstand voltage: 125 V AC, 40 V DC
Connector: Removable terminal block (12 pins) x 2
Settable for each audio input and RS LINK (A/B)
Parametric equalizer: 20 Hz – 20 kHz, ±15 dB, Q: 0.267 – 69.249
Filtering: High-pass filter 20 Hz – 20 kHz, 6 dB/oct, 12 dB/oct
Low-pass filter 20 Hz – 20 kHz, 6 dB/oct, 12 dB/oct
High shelving filter 6 – 20 kHz, ±15 dB
Low shelving filter 20 – 500 Hz, ±15 dB
Notch filter (amplifier output only) 20 Hz – 20 kHz, Q: 8.651 – 69.249
All-pass filter (amplifier output only) 20 Hz – 20 kHz, Q: 0.267 – 69.249
Horn equalizer (amplifier output only) 20 kHz, 0 to +18 dB (0.5 dB steps)
Ratio: 1:1, 1.1:1, 1.2:1, 1.3:1, 1.5:1, 1.7:1, 2:1, 2.3:1, 2.6:1, 3:1, 4:1, 5:1, 7:1, 8:1, 10:1, 12:1, 20:1, ∞:1
Attack time: 0.2 ms – 5 s
Release time: 10 ms – 5 s
Gain: –∞ to +10 dB
Knee type: hard knee, middle knee, soft knee
Sensor input reference level fine adjustment
Maximum output signal level control: –15 to 0 dB
Minimum output signal level control: –18 to –3 dB
Sample time setting: 10 s, 20 s, 30 s, 1 min, 5 min
Gain ratio setting: (Ambient noise: Output signal level) 6:3, 5:3, 4:3, 3:3, 3:4, 3:5, 3:6
Ambient noise measuring frequency setting: 20 Hz – 20 kHz, 3 points
Daily program: 50 events, 10 types
Holiday program: 50 types
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (17 pins) ... 1
Fault Detection System: Short circuit, Open circuit, Ground fault,
Method: Impedance or End of line
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (2 pins) x 2
DA CONTROL LINK x 4,
DA OUTPUT LINK x 4 (Used only when a power amplifier module is installed)
FAULT STATUS (yellow): GENERAL x 1, UNIT x 1, NETWORK x 1, EMG MIC x 1, FUSE x 1, POWER x 1, CPU x 1, ZONE x 8
AMPLIFIER: PEAK (red) x 4, SIGNAL (green) x 4, OPERATE (green) x 4, POWER (green) x 4
Test Switch x 1 (LAMP TEST)
Setting Switch: ID NUMBER, RESET, IMPEDANCE, Setting (internal front panel)
(*2) 0 dB = 1 V
(*3) Module: Digital power amplifier module, Line output module
請下載資料以獲取完整規格。
Frame for 4 amplifier modules with 4 monitored AB speaker outputs.
One amplifier module can optionally be configured as a standby amplifier.
Speaker line monitoring is possible by impedance surveillance or by using an end-of-line module.
Settings for impedance deviation to indicate an open or shorted line can be individually set for every output.
4 general balanced audio inputs (microphone/line level) and 2 inputs for up to 8 remote microphones including up to two emergency microphones.
The general audio signals of the audio inputs can be mixed.
All mandatory indications and controls regarding EN54-16 are on the front panel.
Fault indication for each speaker line.
Redundant network connection (Ethernet) of the frame with RSTP via two RJ45 ports.
請登入以存取更多技術資料,例如軟體、韌體或EASE檔案。