DA-250FH
4頻道數碼功率放大器
DA-250FH
DA-250FH是一款4頻道數碼功率擴音器,每個頻道均提供250W(4Ω)輸出功率。
外型僅為1U,不佔用機櫃空間。
- 內建4組輸入及4組輸出,可由開關切換,組成1入2出/ 1入3出* / 1入4出 / 2入2出 / 3入3出* / 4入4出等,共8種切換模式
- 4組獨立交換式電源(Switching Power),任一頻道故障也不會中斷其它頻道動作
*0 dB = 0.775 V
電源
220 - 240 V AC, 50/60 Hz
Amplification System
Class D
消耗功率
294 W (based on EN standards)
1150 W (rated output 100 V line, 40 Ω x 4)
1150 W (rated output 100 V line, 40 Ω x 4)
輸入
4 circuits, +4 dB* (1.23 V) (input level control in maximum position),
10 kΩ, electronically-balanced, removable terminal block (3 pins)
CH 1 mode ON/OFF switch (ON: CH 1 to All ch, OFF: Each ch)
10 kΩ, electronically-balanced, removable terminal block (3 pins)
CH 1 mode ON/OFF switch (ON: CH 1 to All ch, OFF: Each ch)
額定輸出
4 channels: 250 W x 4 (100 V line, 40 Ω)
M4 screw terminal, distance between barriers: 8.8 mm (0.35)
M4 screw terminal, distance between barriers: 8.8 mm (0.35)
頻率響應
50 Hz - 20 kHz (-3 dB, +1 dB)
總諧波失真
0.1 % (1 kHz)
0.3 % (100 Hz - 20 kHz)
0.3 % (100 Hz - 20 kHz)
S/N比
100 dB (A-weighted)
Crosstalk
70 dB (A-weighted)
回路保護
Protection against excessive current flow due to overload,
short circuit, unusual DC voltage output,
temperature rise at power amp. heat sink (110 °C (230 °F) or more),
temperature rise inside the unit (80 °C (176 °F) or more)
short circuit, unusual DC voltage output,
temperature rise at power amp. heat sink (110 °C (230 °F) or more),
temperature rise inside the unit (80 °C (176 °F) or more)
LED指示燈
Power (blue) x 1, Input (green) x 4, Output (yellow) x 4,
Peak (red) x 4, Protect (red) x 4
Peak (red) x 4, Protect (red) x 4
Cooling
Forced air cooling
工作溫度
-10 °C to +40 °C (14 °F to 104 °F)
工作濕度
90 %RH or less (no condensation)
外觀
Panel: Aluminum, black, alumite
Case: Plated steel sheet
Case: Plated steel sheet
尺寸
482 (W) x 44 (H) x 401.8 (D) mm (18.98 x 1.73" x 15.82")
重量
6.8 kg (14.99 lb)
附屬品
Power cord (2 m (6.56 ft) …1, Removable terminal plug (3 pins) …4,
Tamper-proof cap …4, Rack mounting screw (with plain washer) …4
Tamper-proof cap …4, Rack mounting screw (with plain washer) …4
選配品
Matching transformer: MT-251H
請下載資料以獲取完整規格。
The multi-channel power amplifier shall use digital class-D circuit topology and shall be configurable to allow two, three or four channel operation. Power output in four-channel mode with all channels driven shall be: 250 W per channel into 40 ohms (100 volts). Total harmonic distortion (THD) shall be less than 0.1% at 1 kHz and less than 0.3% from 100 to 20,000 Hz. Frequency response shall be 50 to 20,000 Hz (-3 dB, +1 dB). Signal to noise ratio shall be 100 dB below rated output (A weighted). Crosstalk shall be better than 70 dB (A weighted). Input sensitivity shall be +4 or -10 dBv (jumper selectable) for rated output, where 0 dBv = 0.775 volts RMS. Input impedance shall be 10k ohms for each side of an electronically balanced input circuit. A rear-panel input mode switch shall allow the selection of "channel 1 to all" mode, whereby the signal feeding the channel 1 input terminals is simultaneously fed to all other channels. Rear panel input connector shall be a 3-pin removable terminal block for each channel. Rear panel output connector shall be a heavy-gauge M4 screw-terminal barrier strip suitable for spade lugs or up to #12 AWG bare wire. The front-panel attenuators shall be recessed to prevent accidental level changes and may be removed and replaced by included security covers once levels have been properly set. The front panel shall have four sets of four LED indicators to indicate the following conditions for each channel: signal presence at input (greater than -20 dBv), signal presence at output (greater than 1 W at 40 ohms), peak clipping, and protection circuit activation. The front panel shall also have removable air filters that may be cleaned and reinstalled without removing the amplifier from a rack. The amplifier shall be forced-air fan cooled with the air intake at the front and exhaust at the rear. Built-in protection circuitry shall monitor Voltage and current levels to minimize potential damage from overloads, and disable output during shorts, DC offset, excessive operating temperature at power amp heat sink over 167°F (110°C) via a relay for each channel or excessive temperatures inside the unit over 176°F ( 80°C). The relay shall also delay amplifier connection to the load during turn-on for about 2 seconds, so as to prevent any concurrence of noise at turn-on. Power consumption shall be no more than 200 W when all channels are driven with continuous pink noise at 1/8 full power into 40 ohms (Based on EN standard), and no more than 1,150 W when all channels are driven with continuous pink noise at full rated power into 40 ohms.
The amplifier shall use only one standard rack-space or 44.5 mm(1.75") and its dimensions shall be 482(W) x 401.8(D) x 44(H) mm (18.98" x 15.82" x 1.73"). Front panel finish shall be black anodized aluminum and case finish shall be sheet steel. Weight shall be 6.8 kg (15.0 lbs.).
The amplifier shall be TOA model DA-250FH.
The optional 1:1 line isolation transformer shall be TOA model MT-251H
請登入以存取更多技術資料,例如軟體、韌體或EASE檔案。