SX-2000SM
System Manager
SX-2000SM
The SX-2000SM System Manager is designed for use in TOA's Matrix System and can be mounted in an EIA Standard component rack (1-unit size). It can be used in combination with an optional audio input unit audio output unit and remote microphone of the SX-2000 Series to make up a complete matrix system and can perform audio signal routing and priority control for the entire system. The SX-2000SM itself is equipped with 8 control inputs, 8 control outputs, failure status outputs, failure data inputs/switches, access indicators, mode indicators and failure indicators enabling a wide range of controls and status monitoring. Control input line failure can be detected by connecting resistors to its line. The SX-2000SM has a function to supply a stabilized 24 V DC. Each control can be performed by way of a CF card inserted into the SX-2000SM unit. Operations of the entire system can be recorded and their contents stored on a CF card as an operation log. The SX-2000SM also features two power inputs making possible the creation of a dual-redundant power system. Equipped with two channels of interfaces for connecting to the Emergency Power Supply units, making it possible to configure the system to operate during a power failure.
- Matrix system in combination with an audio input unit, audio output unit and remote microphone
- Audio signal routing and priority control
- 8 control inputs, 8 control outputs
- Failure status outputs, failure data inputs/switches
- Access indicators, mode indicators and failure indicators enabling a wide range of controls and status monitoring
- Control can be performed by way of a CF card inserted into the SX-2000SM unit
- Operations can be recorded and their contents stored on a CF card as an operation log
- Two power inputs for creation of a dual-redundant power system
- Automatic voice announcement for emergency purpose available
- System settings via LAN connection
24 V DC (operational range: 20 V - 40 V DC)
Two power inputs construction enables dual- redundant power supply.
0.8 A or less (when operated on 24 V DC)
LAN access indicator: 1
Mode indicator: 3 (EMERGENCY/STANDBY/ CPU OFF)
Failure indicator: 3 (GENERAL/CPU/SX LINK)
Power indicator: 1 (POWER)
Run indicator: 1 (RUN)
Failure control switch: 3 (ACK/RESET/LAMP TEST)
Audio input: Max. 64 ch
Audio output: Max. 256 zones
Contact input: Max. 1416
Contact output: Max. 1416
Priority control: 512 steps
Event log: Up to 1,000 logs per file (up to 100 files available)
Failure log: Up to 100 logs per file (up to 100 files available)
Connectable SX-2000AO/2100AO No.: Max. 32 units
Connectable SX-2000CI No.: Max. 32 units
Connectable SX-2000CO No.: Max. 32 units
Connectable RM-200SA/SF No.: Max. 64 units (up to 8 RM-200SA per SX-2100AI)
(Connect SX-2100AI and SX-2000AO/2100AO via the switching hub specified by TOA.)
Note: This network must be made completely independent from other LAN.
Connection resitance to make the function active: 10 kΩ ±5%
Connector cable: Twisted pair cable (shielded type is recommended)
Maximum cable distance : 10 m
Case: Surface-treated steel plate
Please download Datasheet to access full specifications.
System Manager, central control unit of the voice alarm system for installation in 19-inch cabinet racks (IEC 60297).
Separate ads for:
-Mode: emergency/standby/analog reserve way
-Activity LAN connection
-Activity of the audio and control network
-Errors: General/CPU/audio and control network
-Power supply
-Operation
Separate buttons for:
-Acknowledgement of fault messages
-Resetting the fault signal
-Lamp test
Acoustic warning in case of a malfunction in accordance with the relevant standards for voice alarm systems.
Redundant power supply for reliable power supply. Two network connections (100BaseTX) for redundant network for audio and control signals, additional analog reserve way. LAN connection to read the system activity, errors and operating conditions, as well as to set the system time. 8 Control inputs with opto-couplers and 8 control outputs with relay changeover contacts via pluggable connectors. Each input can be monitored either.
Two connectors for the monitoring of emergency equipment. Separate control outputs for the above mentioned error messages, E.g. to the forwarding and the BMZ.
The programming software included with the delivery.
Need other technical materials like software? Please visit Download Center.